更多>>产品目录
 
   +  物理仪器
   +  新能源
   +  机器人
   +  机械装备
   +  汽车实训
您现在的位置:网站首页 >> 产品展示
用于示波器的 SignalVu VSA
时间:2016-7-8

SignalVu RF and vector signal analysis software combines the signal analysis engine of the RSA5000 Series real-time spectrum analyzer with that of the industry's leading digital oscilloscopes, making it possible for designers to evaluate complex signals without an external down converter. You get the functionality of a vector signal analyzer, a spectrum analyzer, and the powerful trigger capabilities of a digital oscilloscope - all in a single package. You can use SignalVu with an MSO/DPO5000, DPO7000, or DPO/DSA/MSO70000 Series digital oscilloscope to easily validate wideband designs and characterize wideband spectral events. Whether your design validation needs include wideband radar, high data rate satellite links, wireless LAN, WiGig IEEE 802.11ad, or frequency-hopping communications, SignalVu can speed your time-to-insight by showing you the time-variant behavior of these wideband signals.

Key features
  • Trigger
    • Integrated RF signal analysis package lets you take full advantage of oscilloscope settings
    • Pinpoint? triggering offers over 1400 combinations to address virtually any triggering situation
  • Capture
    • Direct observation of microwave signals without need of an external down converter
    • All signals up to the analog bandwidth of oscilloscope are captured into memory
    • Customize oscilloscope acquisition parameters for effective use of capture memory
    • FastFrame segmented memory captures signal bursts without storing the signal's off time
    • Supports RF, I and Q, and differential I and Q signals using the oscilloscope's 4 analog inputs
  • Analyze
    • time-correlated, multidomain displays connect events in time, frequency, phase, and amplitude for quicker understanding of cause and effect when troubleshooting
    • Power measurements and signal statistics help you characterize components and systems: SEM, Multicarrier ACLR, Power vs. Time, CCDF, OBW/EBW, and Spur Search
    • WLAN spectrum and modulation transmitter measurements based on IEEE 802.11 a/b/g/j/p/n/ac standards (Opts. SV23, SV24, and SV25)
    • WiGig IEEE 802.11ad Spectral and modulation transmitter measurements (Opt. SV30)
    • Bluetooth® Transmitter Measurements based on Bluetooth SIG RF Specifications for Basic Rate and Low Energy. Some support of Enhanced Data Rate. (Option SV27)
    • LTE? FDD and TDD Base Station (eNB) Transmitter RF measurements (Option SV28)
    • Complete APCO Project 25 transmitter testing and analysis for Phase 1 (C4FM) and Phase 2 (TDMA) (Opt. SV26)
    • AM/FM/PM Modulation and Audio Measurements (Opt. SVA) for characterization of analog transmitters and audio signals
    • Settling Time Measurements, Frequency, and Phase (Opt. SVT) for characterization of wideband frequency-agile oscillators
    • Advanced Signal Analysis Suite (Opt. SVP) - Automated pulse measurements provide deep insight into pulse train behavior
    • General Purpose Digital Modulation Analysis (Opt. SVM) provides vector signal analyzer functionality
    • Flexible OFDM analysis (Opt. SVO) with support for 802.11a/g/j and WiMAX 802.16-2004 signals
    • Frequency offset control for analyzing baseband signals with near-zero intermediate frequencies (IF)
    • Tektronix OpenChoice® makes for easy transfer to a variety of analysis programs such as Excel and Matlab
Applications
  • Wideband radar and pulsed RF signals
  • Frequency agile communications
  • Broadband satellite and microwave backhaul links
  • Wireless LAN, WiGig, Bluetooth, Commercial Wireless
  • Land Mobile Radio (LMR), APCO P25
  • Long Term Evolution (LTE), Cellular

Wideband signal characterization

SignalVu helps you easily validate wideband designs and characterize wideband spectral events using an MSO/DPO5000, DPO7000, or DPO/DSA/MSO70000 Series digital oscilloscope. Users can easily switch between the SignalVu application and the oscilloscope's user interface to optimize the collection of wideband signals.

Trigger

SignalVu software works seamlessly with the oscilloscope allowing users to utilize all of its powerful triggering capabilities. The ability to trigger on time- and amplitude-varying events of interest is paramount in wideband system design, debug, and validation. The Tektronix oscilloscopes' trigger systems allow selection of virtually all trigger types on both A and B trigger events whether they be transition, state, time, or logic qualified triggers. Once triggered, SignalVu processes the acquisition for analysis in multiple domains.




Powerful oscilloscope triggers allow the user to capture only the relevant portion of wideband signals. Pinpoint trigger functions such as combining A and B events with Edge with Holdoff can capture a pulse train during a specific transmitter mode of operation.

Capture

Capture once - make multiple measurements without recapturing. All signals in an acquisition bandwidth are recorded into the oscilloscope's deep memory. Up to four channels can be captured simultaneously; each of which can be independently analyzed by SignalVu software. Channels can be RF, I and Q, or differential inputs. Users can also apply math functions to the acquisition prior to analysis by SignalVu. Acquisition lengths vary depending upon the selected capture bandwidth - up to 25 ms can be captured on a single channel with the MSO/DPO5000 Series, up to 12.5 ms can be acquired on a single channel with the DPO7000 Series, and up to 2.5 ms can be captured on a single channel with the DPO/DSA/MSO70000 Series. Significantly longer capture times can be realized with lower oscilloscope sample rates.

Using the FastFrame segmented memory feature in SignalVu enables you to capture events of interest, such as low duty cycle pulsed signals, while conserving acquisition memory. Using multiple trigger events, FastFrame captures and stores short-duration, bursty signals and passes them to SignalVu vector signal analysis functions. Capturing thousands of frames is possible, so long-term trends and changes in the bursty signal can be analyzed.


Once captured into memory, SignalVu provides detailed analysis in multiple domains. The spectrogram display (left panel) shows the frequency of a 500 MHz wide LFM pulse changing over time. By selecting the point in time in the spectrogram during the On time of the pulse, the chirp behavior can be seen as it sweeps from low to high (upper right panel).

Analyze

SignalVu RF and vector signal analysis software uses the same analysis capabilities found in the RSA5000 Series real-time spectrum analyzers. SignalVu advances productivity for engineers working on components or in wideband RF system design, integration, and performance verification, or operations engineers working in networks, or spectrum management. In addition to spectrum analysis, spectrograms display both frequency and amplitude changes over time. Time-correlated measurements can be made across the frequency, phase, amplitude, and modulation domains. This is ideal for signal analysis that includes frequency hopping, pulse characteristics, modulation switching, settling time, bandwidth changes, and intermittent signals.

SignalVu can process RF, I and Q, and differential I and Q signals from any one of the four available oscilloscope inputs. Math functions applied by the oscilloscope are also utilized by SignalVu allowing users to apply custom filtering prior to vector signal analysis.

The Microsoft Windows environment makes this multidomain analysis even easier with an unlimited number of analysis windows, all time-correlated, to provide deeper insight into signal behavior. A user interface that adapts to your preferences (keyboard, front panel, touch screen, and mouse) makes learning SignalVu easy for both first-time users and experienced hands.


Time-correlated, multidomain view provides a new level of insight into design or operational problems not possible with conventional analysis solutions. Here, the hop patterns of a narrowband signal can be observed using Spectrogram (lower right) and its hop characteristics can be precisely measured with Frequency vs Time display (lower left). The time and frequency responses can be observed in the two top views as the signal hops from one frequency to the next.

Options tailored for your wideband applications

SignalVu RF and vector signal analysis software is available for all MSO/DPO5000, DPO7000, and DPO/DSA/MSO70000 Series oscilloscopes and offers options to meet your specific application, whether it be wideband radar characterization, broadband satellite, or spectrum management. SignalVu Essentials (Opt. SVE) provides the fundamental capability for all measurements and is required for pulse analysis (Opt. SVP), settling time (Opt. SVT), digital modulation analysis (Opt. SVM), flexible OFDM analysis (Opt. SVO, not offered on MSO/DPO5000), and AM/FM/PM Modulation and Audio Measurements (Opt. SVA).


Wideband satellite and point-to-point microwave links can be directly observed with SignalVu analysis software. Here, General Purpose Digital Modulation Analysis (Opt. SVM) is demodulating a 16QAM backhaul link running at 312.5 MS/s.




Settling time measurements (Opt. SVT) are easy and automated. The user can select measurement bandwidth, tolerance bands, reference frequency (auto or manual), and establish up to 3 tolerance bands vs. time for Pass/Fail testing. Settling time may be referenced to external or internal trigger, and from the last settled frequency or phase. In the illustration, frequency settling time for a hopped oscillator is measured from an external trigger point from the device under test.

WLAN transmitter testing

With the WLAN measurement options, you can perform standards-based transmitter measurements in the time, frequency, and modulation domains.

  • Option SV23 supports IEEE 802.11a, b, g, j and p signals
  • Option SV24 supports IEEE 802.11n 20 MHz and 40 MHz SISO signals
  • Option SV25 supports IEEE 802.11ac 20/40/80/160 MHz SISO signals

The table below described the modulation formats and frequency bands of IEEE 802.11 WLAN signals

Standard Std PHY Freq band(s) Signal Modula­tion formats Band­width (max) 802.11- 2012 section
802.11b DSSS HR/DSSS 2.4 GHz DSSS/CCK 1 - 11 Mbps DBSK, DQPSK CCK5.5M, CCK11M 20 MHz 16 & 17 
802.11g ERP 2.4 GHz DSSS/CCK/PBCC 1 - 33 Mbps BPSK DQPSK 20 MHz 17 
802.11a OFDM 5 GHz OFDM 64  <54 Mbps BPSK QPSK
16QAM
64QAM
20 MHz 18 
802.11g 2.4 GHz 20 MHz 19 
802.11j/p 5 GHz 5, 10, 20 MHz 18 
802.11n HT 2.4 GHz & 5 GHz OFDM 64, 128  ≤ 150 Mbps BPSK QPSK
16QAM
64QAM
20 , 40 MHz 20 
802.11ac VHT 5 GHz OFDM 64, 128, 256, 512  ≤ 867 Mbps BPSK QPSK
16QAM
64QAM
256QAM
20, 40, 80, 160 MHz 22 

The Frequency Band (Freq Band(s)) provides the minimum requirement for the bandwidth of the oscilloscope to use.

Inside SignalVu, the WLAN presets make the EVM, Constellation and SEM measurements push-button. The WLAN RF transmitter measurements are defined by the IEEE 802.11- 2012 revision of the standard and listed below with the reference to the section and the limit to reach.




Easy analysis of WLAN 802.11ac transmitter with a WLAN preset that provides spectral emission mask, constellation diagram, and decoded burst information.

WiGig IEEE802.11ad transmitter testing

Option SV30 provides WiGig IEEE802.11ad standard transmitter measurements. Used together with the DPO77002SX, it delivers industry’s best accurate signal quality measurement at 60GHz. It allows you to automatically detect the packet start, synchronize to preamble using the Golay codes in the short training field and demodulate preamble, header, and payload separately. These different fields are color coded in the User Interface. This option also measures EVM in each of the packet fields per the standard, and decodes the header packet information. In addition RF power, Received Channel Power Indicator, Frequency error, IQ DC origin offset, IQ Gain and Phase imbalance are reported in the Summary display. Pass/Fail results are reported using customizable limits and the presets make the test set-up push-button. Both Control PHY and Single Carrier PHY are supported and the measurements listed above can be done at RF or at IF. For further insight into the signal, you can also visualize the EVM spread across the analyzed packet with color codes differentiating fields and color coded demodulated symbols in tabular form with an option to traverse to the start of each field for easier navigation.


DPO77002SX SV30 provides industry best EVM accuracy. It allows easy setup to perform transmitter measurements including time overview of the bursts, spectrum, constellation diagram, decoded burst information and EVM measurements.

Bluetooth transmitter testing

With option SV27, you can perform Bluetooth SIG standard-based transmitter RF measurements in the time, frequency, and modulation domains. Option SV27 supports Basic Rate and Low Energy Transmitter measurements defined by Bluetooth SIG Test Specification RF.TS.4.2 for Basic Rate and RF-PHY.TS.4.2 for Bluetooth Low Energy. Option SV27 also automatically detects Enhanced Data Rate packets, demodulates them and provides symbol information.

Pass/Fail results are provided with customizable limits and the Bluetooth presets make the different test set-ups push-button.

Below is a summary of the measurements that are automated with option SV27 (unless noted):

  • Bluetooth Low Energy Transmitter Measurements
    • Output power at NOC TRM-LE/CA/01/C and at EOC TRM-LE/CA/02/C
    • In-band emission at NOC TRM-LE/CA/03/C and at EOC TRM-LE/CA/04/C
    • Modulation characteristics TRM-LE/CA/05/C
    • Carrier frequency offset and drift at NOC TRM-LE/CA/06/C and at EOC TRM-LE/CA/07/C
  • Basic Rate Transmitter Measurements
    • Output power TRM/CA/01/C
    • Power Density TRM/CA/02/C (no preset)
    • Power Control TRM/CA/03/C (no preset)
    • Tx output Spectrum – Frequency Range TRM/CA/04/C (no preset)
    • Tx output spectrum - 20dB Bandwidth TRM/CA/05/C
    • Tx output spectrum - Adjacent Channel Power TRM/CA/06/C
    • Modulation characteristics TRM/CA/07/C
    • Initial carrier frequency tolerance TRM/CA/08/C
    • Carrier frequency-drift TRM/CA/09/C

The following additional information is also available with SV27: symbol table with color coded field information, constellation, eye diagram, frequency deviation vs time with highlighted packet and octet, frequency offset and drift detailed table as well as packet header field decoding. Markers can be used to cross-correlate the time, vector and frequency information.


Easy validation of Bluetooth transmitter with push button preset, pass/fail information and clear correlation between displays.

LTE FDD and TDD base station transmitter RF testing

Option SV28 enables the following LTE measurements:

  • Cell ID

  • Channel Power

  • Occupied Bandwidth

  • Adjacent Channel Leakage Ratio (ACLR)

  • Spectrum Emission Mask (SEM)

  • Transmitter Off Power for TDD

 

There are four presets to accelerate pre-compliance testing and determine the Cell ID. These presets are defined as Cell ID, ACLR, SEM, Channel Power and TDD Toff Power. The measurements follow the definition in 3GPP TS Version 12.5 and support all base station categories, including picocells and femtocells. Pass/Fail information is reported and all channel bandwidths are supported.

The Cell ID preset displays the Primary Synchronization Signal (PSS) and the Secondary Synchronization Signal (SSS) in a Constellation diagram. It also provides Frequency Error.

The ACLR preset measures the E-UTRA and the UTRA adjacent channels, with different chip rates for UTRA. ACLR also supports Noise Correction based on the noise measured when there is no input. Both ACLR and SEM will operate in swept mode (default) or in faster single acquisition if the instrument has enough acquisition bandwidth.


Fast validation of LTE base station transmitter with push button preset, and pass/fail information

Measurement functions

Spectrum analyzer measurements (Opt. SVE) Channel Power, Adjacent Channel Power, Multicarrier Adjacent Channel Power/Leakage Ratio, Occupied Bandwidth, xdB Down, dBm/Hz Marker, dBc/Hz Marker
Time domain and statistical measurements (Opt. SVE) RF IQ vs. Time, Amplitude vs. Time, Power vs. Time, Frequency vs. Time, Phase vs. Time, CCDF, Peak-to-Average Ratio, Amplitude, Frequency, and Phase Modulation Analysis
Spur search measurements (Opt. SVE) Up to 20 ranges, user-selected detectors (peak, average, CISPR peak), filters (RBW, CISPR, MIL) and VBW in each range. Linear or Log frequency scale. Measurements and violations in absolute power or relative to a carrier. Up to 999 violations identified in tabular form for export in CSV format
WLAN 802.11a/b/g/j/p measurement application (Opt. SV23) All of the RF transmitter measurements as defined in the IEEE standard, and a wide range of additional scalar measurements such as Carrier Frequency error, Symbol Timing error, Average/peak burst power, IQ Origin Offset, RMS/Peak EVM, and analysis displays, such as EVM and Phase/Magnitude Error vs time/frequency or vs symbols/ subcarriers, as well as packet header decoded information and symbol table.
Option SV23 requires Option SVE
Option SV24 requires Option SV23
Option SV25 requires Option SV24
WLAN 802.11n measurement application (Opt. SV24)
WLAN 802.11ac measurement application (Opt. SV25)
APCO P25 compliance testing and analysis application (Opt. SV26) Complete set of push-button TIA-102 standard-based transmitter measurements with pass/fail results including ACPR, transmitter power and encoder attack times, transmitter throughput delay, frequency deviation, modulation fidelity, symbol rate accuracy, and transient frequency behavior, as well as HCPM transmitter logical channel peak ACPR, off slot power, power envelope, and time alignment. Option SV26 requires Option SVE
Bluetooth Basic LE TX SIG measurements (Opt. SV27) Presets for transmitter measurements defined by Bluetooth SIG for Basic Rate and Bluetooth Low Energy. Results also include Pass/Fail information. Application also provides Packet Header Field Decoding and can automatically detect the standard including Enhanced Data Rate.
LTE Downlink RF measurements (Opt. SV28) Presets for Cell ID, ACLR, SEM, Channel Power and TDD Toff Power. Supports TDD and FDD frame format and all base stations defined by 3GPP TS version 12.5. Results include Pass/Fail information. Real-Time settings make the ACLR and the SEM measurements fast, if the connected instrument has enough bandwidth.
WiGig IEEE 802.11ad (Opt. SV30) Presets for Control PHY and Single Carrier PHY. Measures EVM in each of the packet fields per the standard, and decodes the header packet information. RF power, Received Channel Power Indicator, Frequency error, IQ DC origin offset, IQ Gain and Phase imbalance are reported in the Summary display. Pass/Fail results are reported using customizable limits.
AM/FM/PM modulation and audio measurements (Opt. SVA) Carrier Power, Frequency Error, Modulation Frequency, Modulation Parameters (±peak, peak-peak/2, RMS), SINAD, Modulation Distortion, S/N, THD, TNHD, Hum and Noise
Settling time (frequency and phase) (Opt. SVT) Measured Frequency, Settling Time from last settled frequency, Settling Time from last settled phase, Settling Time from Trigger. Automatic or manual reference frequency selection. User-adjustable measurement bandwidth, averaging, and smoothing. Pass/Fail Mask Testing with 3 user-settable zones
Advanced signal analysis (Opt. SVP) Average On Power, Peak Power, Average Transmitted Power, Pulse Width, Rise Time, Fall Time, Repetition Interval (seconds), Repetition Interval (Hz), Duty Factor (%), Duty Factor (ratio), Ripple (dB), Ripple (%), Droop (dB), Droop (%), Overshoot (dB), Overshoot (%), Pulse-Pulse Frequency Difference, Pulse-Pulse Phase Difference, RMS Frequency Error, Max Frequency Error, RMS Phase Error, Max Phase Error, Frequency Deviation, Phase Deviation, Impulse Response (dB), Impulse Response (time), Time Stamp
Flexible OFDM analysis (Opt. SVO) OFDM analysis with support for WLAN 802.11a/g/j and WiMAX 802.16-2004. Constellation, Scalar Measurement Summary, EVM or Power vs. Carrier, Symbol Table (Binary or Hexadecimal)
General purpose digital modulation analysis (Opt. SVM) Error Vector Magnitude (EVM) (RMS, Peak, EVM vs. Time), Modulation Error Ratio (MER), Magnitude Error (RMS, Peak, Mag Error vs. Time), Phase Error (RMS, Peak, Phase Error vs. Time), Origin Offset, Frequency Error, Gain Imbalance, Quadrature Error, Rho, Constellation, Symbol Table. FSK only: Frequency Deviation, Symbol Timing Error


The Advanced Signal Analysis package (Opt. SVP) provides 27 individual measurements to automatically characterize long pulse trains. An 500 MHz wide LFM chirp centered at 1 GHz is seen here with measurements for pulses 1 through 10 (lower right). The shape of the pulse can be seen in the Amplitude vs. Time plot shown in the upper left. Detailed views of pulse #8's frequency deviation and parabolic phase trajectory are shown in the other two views.




Settling time measurements (Opt. SVT) are easy and automated. The user can select measurement bandwidth, tolerance bands, reference frequency (auto or manual), and establish up to 3 tolerance bands vs. time for Pass/Fail testing. Settling time may be referenced to external or internal trigger, and from the last settled frequency or phase. In the illustration, frequency settling time for a hopped oscillator is measured from an external trigger point from the device under test.

Specifications

The following is typical performance of SignalVu®running on any MSO/DPO5000, DPO7000, or DPO/DSA/MSO70000 Series oscilloscopes.

Frequency-related Frequency range See appropriate oscilloscope data sheetInitial center frequency setting accuracy Equal to time-base accuracy of oscilloscopeCenter frequency setting resolution 0.1 HzFrequency offset range 0 Hz to the maximum bandwidth of the oscilloscopeFrequency marker readout accuracy ±(Reference Frequency Error × Marker Frequency + 0.001 × Span + 2) HzSpan accuracy ±0.3%Reference frequency error Equal to oscilloscope reference frequency accuracy, aging, and drift. Refer to appropriate DPO/DSA/MSO data sheet.Tuning Tables

Tables that present frequency selection in the form of standards-based channels are available for the following.

Cellular standards families: AMPS, NADC, NMT-450, PDC, GSM, CDMA, CDMA-2000, 1xEV-DO WCDMA, TD-SCDMA, LTE, WiMax

Unlicensed short range: 802.11a/b/j/g/p/n/ac, Bluetooth

Cordless phone: DECT, PHS

Broadcast: AM, FM, ATSC, DVBT/H, NTSC

Mobile radio, pagers, other: GMRS/FRS, iDEN, FLEX, P25, PWT, SMR, WiMax

3rd order inter-modulation distortion1
Center frequency MSO/DPO5000 DPO7000 DPO/DSA/MSO70000
2 GHz -38 dBc -40 dBc -55 dBc
10 GHz -- -- -48 dBc
18 GHz -- -- -50 dBc

1Conditions: Each signal level -5 dBm, reference level 0 dBm, 1 MHz tone separation. Math traces off. DPO7054/7104 and MSO/DPO5034/5054/5104 performance not listed.

Residual responses1 DPO/DSA/ MSO70000 series (all spans)

–60 dBm

DPO7000C series (all spans)

 

–65 dBm

MSO/DPO5000 series (all spans)

 

–70 dBm

1Conditions: RF input terminated, reference level 0 dBm, measurements made after specified oscilloscope warm-up and SPC calibration. Does not include zero Hz spur.

Displayed average noise level1
Span MSO/DPO5000 DPO7000C DPO/DSA/MSO70000
DC - 500 MHz -94 dBm -100 dBm -103 dBm
>500 MHz - 3.5 GHz - -102 dBm -103 dBm
>3.5 GHz - 14 GHz - - -101 dBm
>14 GHz - 20 GHz - - -88 dBm
>20 GHz - 25 GHz - - -87 dBm
>25 GHz - 33 GHz - - -85 dBm

1Conditions: RF input terminated, 10 kHz RBW, 100 averages, reference level -10 dBm, trace detection average. Measurements made after specified oscilloscope warm-up and SPC calibration. MSO/DPO5034 and MSO/DPO5054 performance not listed.

Input-related Number of inputs1 Input signal types RF, I and Q (single ended), I and Q (differential)Maximum input level +26 dBm for 50 ? input (5 VRMS)

1SignalVu can process acquisitions from any one of the oscilloscope channels. Users can also apply custom math and filter functions to each of the oscilloscope's acquisition channels. The resulting Math channel can then be selected by SignalVu for signal processing.

Trigger-related Trigger modes Free Run and Triggered. Trigger sensitivity and characteristics can be found in the appropriate oscilloscope data sheet.Acquisition-related SignalVu provides long acquisitions of waveform captures with high time and frequency resolution. Maximum acquisition time will vary based on the oscilloscope's available memory and analog bandwidth. The following table highlights each model's single-channel capabilities given its maximum available memory configuration. 

Model1

Max span

Max acquisition time at max sample rate

Min RBW at max sample rate

Min IQ time resolution

Max number of FastFrames2

DPO/DSA73304D 33 GHz 2.5 ms 1.2 kHz 20 ps 65,535 
DPO/DSA72504D 25 GHz
DPO/DSA/ MSO72004C 20 GHz
DPO/DSA/ MSO71604C 16 GHz
DPO/DSA/ MSO71254C 12.5 GHz
DPO/DSA/ MSO70804C 8 GHz 5 ms 600 Hz 80 ps
DPO/DSA/ MSO70604C 6 GHz
DPO/DSA/ MSO70404C 4 GHz
DPO7354C 3.5 GHz 12.5 ms 300 Hz 50 ps
DPO7254C 2.5 GHz
DPO7104C 1 GHz 100 ps
DPO7054C 500 MHz
MSO/DPO5204 2 GHz 25 ms 100 Hz 200 ps
MSO/DPO5104 1 GHz
MSO/DPO5054 500 MHz 400 ps
MSO/DPO5034 350 MHz

1With maximum available record length option and maximum sample rate.

2Maximum number of frames available will depend upon the oscilloscope's record length, sample rate, and the acquisition length settings.

Analysis-related Frequency (Opt. SVE)

Spectrum (Amplitude vs. Linear or Log Frequency)

Spectrogram (Amplitude vs. Frequency over Time)

Spurious (Amplitude vs. Linear or Log Frequency)

Time and statistics (Opt. SVE)

Amplitude vs. Time

Frequency vs. Time

Phase vs. Time

Amplitude Modulation vs. Time

Frequency Modulation vs. Time

Phase Modulation vs. Time

RF IQ vs. Time

Time Overview

CCDF

Peak-to-Average Ratio

Settling time, frequency, and phase (Opt. SVT)

Frequency Settling vs. Time

Phase Settling vs. Time

Advanced measurements suite (Opt. SVP)

Pulse results Table

Pulse trace (Selectable by pulse number)

Pulse statistics (Trend of pulse results, FFT of trend, and histogram)

Digital demod (Opt. SVM)

Constellation diagram

EVM vs. Time

Symbol table (binary or hexadecimal)

Magnitude and Phase Error vs. Time, and Signal Quality

Demodulated IQ vs. Time

Eye diagram

Trellis diagram

Frequency Deviation vs. Time

Flexible OFDM (Opt. SVO) EVM vs. Symbol, vs. SubcarrierSubcarrier Power vs. Symbol, vs. SubcarrierSubcarrier constellationSymbol data tableMag Error vs. Symbol, vs. SubcarrierPhase Error vs. Symbol, vs. SubcarrierChannel frequency responseSupported file formats SignalVu can recall saved acquisitions from MSO/DPO5000, DPO7000, DPO/DSA/MSO70000, RSA5000, and RSA6000 Series instruments. Both WFM and TIQ file extensions can be recalled for postprocessing by SignalVu.
RF and spectrum analysis performance
Resolution bandwidth Resolution bandwidth (spectrum analysis) 1, 2, 3, 5 sequence, auto-coupled, or user selected (arbitrary)Resolution bandwidth shape Approximately Gaussian, shape factor 4.1:1 (60:3 dB) ±10%, typicalResolution bandwidth accuracy ±1% (auto-coupled RBW mode)Alternative resolution bandwidth types Kaiser window (RBW), –6 dB Mil, CISPR, Blackman-Harris 4B window, Uniform window (none), flat-top window (CW ampl.), Hanning windowVideo bandwidth Video bandwidth range Dependent on oscilloscope record length setting. approximately 500 Hz to 5 MHzRBW/VBW maximum 10,000:1 RBW/VBW minimum 1:1 Resolution 5% of entered valueAccuracy (typical) ±10%Time domain bandwidth (amplitude vs. time display) Time domain bandwidth range At least 1/2 to 1/10,000 of acquisition bandwidthTime domain bandwidth shape

Approximately Gaussian, shape factor 4.1:1(60:3 dB), ±10% typical

Shape factor <2.5:1 (60:3 dB) typical for all bandwidths

Time domain bandwidth accuracy ±10%Spectrum display traces, detectors, and functions Traces Three traces + 1 math trace + 1 trace from spectrogram for spectrum displayDetector Peak, –peak, average, CISPR peakTrace functions Normal, Average, Max Hold, Min HoldSpectrum trace length 801, 2401, 4001, 8001, or 10401 points
AM/FM/PM modulation and audio measurements (SVA)1

1All published performance based on conditions of Input Signal: 0 dBm, Input Frequency: 100 MHz, RBW: Auto, Averaging: Off, Filters: Off. Sampling and input parameters optimized for best results.

Analog demodulation1 Carrier frequency range 1 kHz or (1/2 × audio analysis bandwidth) to maximum input frequencyMaximum audio frequency span 10 MHz

1Sampling rates of the oscilloscope are recommended to be adjusted to no more than 10X the audio carrier frequency for modulated signals, and 10X the audio analysis bandwidth for direct input audio. This reduces the length of acquisition required for narrow-band audio analysis.

Audio filters Low pass (kHz) 0.3, 3, 15, 30, 80, 300, and user-entered up to 0.9 × audio bandwidthHigh pass (Hz) 20, 50, 300, 400, and user-entered up to 0.9 × audio bandwidthStandard CCITT, C-MessageDe-emphasis (μs) 25, 50, 75, 750, and user-enteredFile User-supplied .TXT or .CSV file of amplitude/frequency pairs. Maximum 1000 pairs.FM modulation analysis FM measurements, Dev./(Mod. Rate) > 0.1  Carrier power, carrier frequency error, audio frequency, deviation (+peak, –peak, peak-peak/2, RMS), SINAD, modulation distortion, S/N, total harmonic distortion, total non-harmonic distortion, hum and noiseFM deviation accuracy (rate: 1 kHz, deviation: 1 kHz to 100 kHz) ±1.5% of deviationFM rate accuracy (rate: 1 kHz to 100 kHz, deviation: 1 kHz to 100 kHz) ±1.0 HzCarrier frequency accuracy (deviation: 1 kHz to 10 kHz) ±1 Hz + (transmitter frequency × reference frequency error)Residuals (FM) (rate: 1 kHz to 10 kHz, deviation: 5 kHz) THD

0.2% (MSO/DPO7000, 70000 Series)

1.0% (MSO/DPO5000 Series)

SINAD

44 dB (MSO/DPO7000, 70000 Series)

38 dB (MSO/DPO5000 Series)

AM modulation analysis AM measurements Carrier power, audio frequency, modulation depth (+peak, –peak, peak-peak/2), RMS, SINAD, modulation distortion, S/N, total harmonic distortion, total non-harmonic distortion, hum and noiseAM depth accuracy (rate: 1 kHz, depth: 50%) ±1% + 0.01 × measured valueAM rate accuracy (rate: 1 kHz, depth: 50%) ±1.0 HzResiduals (AM) THD

0.3% (MSO/DPO7000, 70000 Series)

1.0% (MSO/DPO5000 Series)

SINAD

48 dB (MSO/DPO7000, 70000 Series)

43 dB (MSO/DPO5000 Series)

PM modulation analysis PM measurement Carrier power, carrier frequency error, audio frequency, deviation (+peak, –peak, peak-peak/2, RMS), SINAD, modulation distortion, S/N, total harmonic distortion, total non-harmonic distortion, hum and noisePM deviation accuracy (rate: 1 kHz, deviation: 0.628 rad) ±100% × (0.01 + (rate / 1 MHz))PM rate accuracy (rate: 1 kHz, deviation: 0.628 rad) ±1 HzResiduals (PM) THD

0.1% (MSO/DPO7000, 70000 Series)

0.5% (MSO/DPO5000 Series)

SINAD

48 dB (MSO/DPO7000, 70000 Series)

43 dB (MSO/DPO5000 Series)

  Direct audio input Audio measurements Signal power, audio frequency (+peak, –peak, peak-peak/2, RMS), SINAD, modulation distortion, S/N, total harmonic distortion, total non-harmonic distortion, hum and noiseDirect input frequency range (for audio measurements only)

1 Hz to 10 MHz

Maximum audio frequency span

10 MHz

Audio frequency accuracy ±1 HzResiduals (PM) THD

1.5%

SINAD

38 dB

  Minimum audio analysis bandwidth and RBW vs. oscilloscope memory and sample rate (Opt. SVA)
Model Sample rate: 1 GS/s Sample rate: maximum
Standard memory Maximum memory Standard memory Maximum memory
Min. Aud. BW RBW (Auto) Min. Aud. BW RBW (Auto) Min. Aud. BW RBW (Auto) Min. Aud. BW RBW (Auto)
MSO/ DPO 5034 
MSO/DPO 5054 
200 kHz 400 Hz 20 kHz 40 Hz 1 MHz 2 kHz 100 kHz 200 hz
MSO/DPO
5104 
MSO/DPO
5204 
100 kHz 200 Hz 10 kHz 20 hz 1 MHz 2 kHz 100 kHz 200 Hz
DPO
7000 
50 kHz 100 Hz 50 kHz 100 Hz 2 MHz 4 kHz 2 MHz 4 kHz
DPO/DSA/ MSO
70000 ≥12.5 GHz BW
200 kHz 400 Hz 10 kHz 20 Hz not recom-mended >4 kHz 1 MHz 2 kHz
DPO/DSA/ MSO 70000 <12.5 GHz BW 200 kHz 400 Hz 20 kHz 40 Hz not recom-mended >4 kHz 500 kHz 1 kHz
Settling time, frequency, and phase (SVT)1

1Settled Frequency or Phase at the measurement frequency. Measured signal level > -20 dBm, Attenuator: Auto.

Settled frequency uncertainty, 95% confidence (typical) Measurement frequency: 1 GHz
Averages Frequency uncertainty at stated measurement bandwidth
1 GHz 100 MHz 10 MHz 1 MHz
Single measurement 20 kHz 2 kHz 500 Hz 100 Hz
100 averages 10 kHz 500 Hz 200 Hz 50 Hz
1000 averages 2 kHz 200 Hz 50 Hz 10 Hz
Measurement frequency: 9 GHz
Averages Frequency uncertainty at stated measurement bandwidth
1 GHz 100 MHz 10 MHz 1 MHz
Single Measurement 20 kHz 5 kHz 2 kHz 200 Hz
100 Averages 10 kHz 2 kHz 500 Hz 50 Hz
1000 Averages 2 kHz 500 Hz 200 Hz 20 Hz
Settled phase uncertainty, 95% confidence (typical) Measurement frequency: 1 GHz
Averages Phase uncertainty at stated measurement bandwidth
1 GHz 100 MHz 10 MHz 1 MHz
Single measurement
100 averages 0.5° 0.5° 0.5° 0.5°
1000 averages 0.2° 0.2° 0.2° 0.2°
Measurement frequency: 9 GHz
Averages Phase uncertainty at stated measurement bandwidth
1 GHz 100 MHz 10 MHz 1 MHz
Single measurement
100 averages
1000 averages 0.5° 0.5° 0.5° 0.5°
Advanced measurement suite (Opt. SVP)
General characteristics Measurements Average On Power, Peak Power, Average Transmitted Power, Pulse Width, Rise Time, Fall Time, Repetition Interval (seconds), Repetition Interval (Hz), Duty Factor (%), Duty Factor (ratio), Ripple (dB), Ripple (%), Droop (dB), Droop (%), Overshoot (dB), Overshoot (%), Pulse-Pulse Frequency Difference, Pulse-Pulse Phase Difference, RMS Frequency Error, Max Frequency Error, RMS Phase Error, Max Phase Error, Frequency Deviation, Phase Deviation, Impulse Response (dB), Impulse Response (time), Time StampNumber of pulses 1 to 10,000 System rise time (typical) Equal to oscilloscope rise timeMinimum pulse width for detection1
Model Minimum PW
DPO/DSA72004B MSO72004 400 ps
DPO/DSA71604B MSO71604 500 ps
DPO/DSA71254B MSO71254 640 ps
DPO/DSA70804B MSO70804 1 ns
DPO/DSA70604B MSO70604 1.3 ns
DPO/DSA70404B MSO70404 2 ns
DPO7354 2.25 ns
DPO7254 3 ns
DPO7104 8 ns
DPO7054 16 ns
MSO/DPO5204 4 ns
MSO/DPO5104 8 ns
MSO/DPO5054 16 ns
MSO/DPO5034 25 ns

1Conditions: Approximately equal to 10/(IQ sampling rate). IQ sampling rate is the final sample rate after digital down conversion from the oscilloscope. Pulse measurement filter set to max bandwidth.

Pulse measurement accuracy (typical)1 Average on power ±0.3 dB + Absolute Amplitude Accuracy of oscilloscopeAverage transmitted power ±0.4 dB + Absolute Amplitude Accuracy of oscilloscopePeak power ±0.4 dB + Absolute Amplitude Accuracy of oscilloscopePulse width ±(3% of reading + 0.5 × sample period)Pulse repetition rate ±(3% of reading + 0.5 × sample period)

1Conditions: Pulse Width > 450 ns, S/N Ratio ≥30 dB, Duty Cycle 0.5 to 0.001, Temperature 18 °C to 28 °C.

Digital modulation analysis (SVM)
Modulation formats π/2DBPSK, BPSK, SBPSK, QPSK, DQPSK, π/4DQPSK, D8PSK, 8PSK, OQPSK, SOQPSK, CPM, 16/32/64/128/256QAM, MSK, GMSK, GFSK, 2-FSK, 4-FSK, 8-FSK, 16-FSK, C4FM, D16PSK, 16APSK, and 32APSKAnalysis period Up to 80,000 samplesMeasurement filters Square-root raised cosine, raised cosine, Gaussian, rectangular, IS-95, IS-95 EQ, C4FM-P25, half-sine, None, User DefinedReference filters Raised cosine, Gaussian, rectangular, IS-95, SBPSK-MIL, SOQPSK-MIL, SOQPSK-ARTM, None, User DefinedAlpha/B x T range 0.001 to 1, 0.001 step 

Constellation, Error vector magnitude (EVM) vs time, Modulation error ratio (MER), Magnitude error vs time, Phase error vs time, Signal quality, Symbol table

rhoFSK only: Frequency deviation, Symbol timing error

Symbol rate range 1 kS/s to (0.4 * Sample Rate) GS/s (modulated signal must be contained entirely within the acquisition bandwidth)Adaptive equalizer Type Linear, decision-directed, feed-forward (FIR) equalizer with coefficient adaptation and adjustable convergence rateModulation types supported BPSK, QPSK, OQPSK π/2 DQPSK, π/4 DQPSK, 8PSK, D8PSK, D16PSK, 16/32/64/128/256QAMReference filters for all modulation types except OQPSK Raised cosine, Rectangular, NoneReference filters for OQPSK Raised cosine, Half sineFilter length 1-128 tapsTaps/symbol: raised cosine, half sine, no filter 1, 2, 4, 8 Taps/symbol: rectangular filter Equalizer controls Off, Train, Hold, Reset16QAM Residual EVM (typical) for DPO7000 and DPO/DSA/MSO70000 series1
Symbol Rate RF IQ
100 MS/s <2.0% <2.0%
312.5 MS/s <3.0% <3.0%

1CF = 1 GHz, Measurement Filter = root raised cosine, Reference Filter = raised cosine, Analysis Length = 200 symbols.

16QAM Residual EVM (typical) for MSO/DPO5000 series1
Symbol Rate RF IQ
10 MS/s 1.5% 1.0%
100 MS/s 4.0% 2.0%

1Carrier frequency 700 MHz. MSO/DPO5054 and MSO/DPO5034 performance not listed. Use of external reference will degrade EVM performance.

OFDM residual EVM, 802.11g Signal at 2.4 GHz, input level optimized for best performance DPO7000 Series –33 dBDPO/DSA/MSO70000 Series –38 dB
WLAN IEEE802.11a/b/g/j/p (Opt. SV23)
General characteristics Modulation formats DBPSK (DSSS1M), DQPSK (DSSS2M), CCK5.5M, CCK11M , OFDM (BPSK, QPSK, 16 or 64QAM)Measurements

RMS and Peak EVM for Pilots/Data, Peak EVM located per symbol and subcarrier

Packet header format information

Average power and RMS EVM per section of the header

WLAN power vs time, WLAN symbol table, WLAN constellation

Spectrum Emission Mask, Spurious

Error vector magnitude (EVM) vs symbol (or time), vs subcarrier (or frequency)

Mag error vs symbol (or time), vs subcarrier (or frequency)

Phase error vs symbol (or time), vs subcarrier (or frequency)

WLAN channel frequency response vs symbol (or time), vs subcarrier (or frequency)

WLAN spectral flatness vs symbol (or time), vs subcarrier (or frequency)

WLAN IEEE802.11n (Opt. SV24)
General characteristics Modulation formats OFDM (BPSK, QPSK, 16 or 64 QAM), SISOMeasurements

Burst index, Burst power, Peak to average burst power, IQ origin offset, Frequency error, Common pilot error, Symbol clock error

RMS and peak EVM for Pilots/Data, peak EVM located per symbol and subcarrier

Packet header format information

Average power and RMS EVM per section of the header

WLAN power vs time, WLAN symbol table, WLAN constellation

Spectrum emission mask, spurious

Error vector magnitude (EVM) vs symbol (or time), vs subcarrier (or frequency)

Mag error vs symbol (or time), vs subcarrier (or frequency)

Phase error vs symbol (or time), vs subcarrier (or frequency)

WLAN channel frequency response vs symbol (or time), vs subcarrier (or frequency)

WLAN spectral flatness vs symbol (or time), vs subcarrier (or frequency)

WLAN IEEE802.11ac (Opt. SV25)
General characteristics Modulation formats OFDM (BPSK, QPSK, 16 QAM, 64 QAM, 256 QAM), SISOMeasurements

Burst index, Burst power, Peak to average burst power, IQ origin offset,Frequency error, Common pilot error, Symbol clock error

RMS and peak EVM for Pilots/Data, Peak EVM located per symbol and subcarrier

Packet header format information

Average power and RMS EVM per section of the header

WLAN Power vs time, WLAN symbol table, WLAN constellation

Spectrum emission mask, spurious

Error vector magnitude (EVM) vs symbol (or time), vs subcarrier (or frequency)

Mag error vs symbol (or time), vs subcarrier (or frequency)

Phase error vs symbol (or time), vs subcarrier (or frequency)

WLAN channel frequency response vs symbol (or time), vs subcarrier (or frequency)

WLAN spectral flatness vs symbol (or time), vs subcarrier (or frequency)

WiGig 802.11ad (Opt. SV30)
Modulation formats Control PHY (DBPSK) , Single Carrier PHY (π/2-BPSK, π/2-QPSK, π/2-16QAM)Measurements and displays RF output power, Received Channel Power Indicator (RCPI), Frequency Error,

Symbol Rate Error, IQ Origin Offset, IQ Gain Imbalance, IQ Quadrature Error,

EVM results for each packet region (STF, CEF, Header and Data), Packet information

includes the Packet type, Preamble, Synchronization Word or Access Code, Packet

Header, Payload length and CRC details.

Residual EVM, measured at RF (58 GHz - 65 GHz) on DPO77002SX1 π/2-BPSK = 1.9%

π/2-QPSK = 2.1%

π/2-16QAM = 2.5%

1Measurement uncertainty: +/- 0.3% points due to pre-compensation filter.

APCO P25 (Opt. SV26)
Modulation formats Phase 1 (C4FM), Phase 2 (HCPM, HDQPSK)Measurements and displays RF output power, operating frequency accuracy, modulation emission spectrum,

unwanted emissions spurious, adjacent channel power ratio, frequency deviation,

modulation fidelity, frequency error, eye diagram, symbol table, symbol rate accuracy,

transmitter power and encoder attack time, transmitter throughput delay, frequency

deviation vs. time, power vs. time, transient frequency behavior, HCPM transmitter logical

channel peak adjacent channel power ratio, HCPM transmitter logical channel off slot power,

HCPM transmitter logical channel power envelope, HCPM transmitter logical channel time alignment

Bluetooth (Opt. SV27)
Modulation formats Basic Rate, Bluetooth Low Energy, Enhanced Data Rate - Revision 4.2 Measurements and displays

Peak Power, Average Power, Adjacent Channel Power or InBand Emission mask, -20 dB Bandwidth, Frequency Error, Modulation Characteristics including ΔF1avg (11110000), ΔF2avg (10101010), ΔF2 > 115 kHz, ΔF2/ΔF1 ratio, frequency deviation vs. time with packet and octet level measurement information, Carrier Frequency f0, Frequency Offset (Preamble and Payload), Max Frequency Offset, Frequency Drift f1-f0, Max Drift Rate fn-f0and fn-fn-5, Center Frequency Offset Table and Frequency Drift table, color-coded Symbol table, Packet header decoding information, eye diagram, constellation diagram

LTE Downlink (Opt. SV28)
Standard Supported 3GPP TS 36.141 Version 12.5 Frame Format supported FDD and TDDMeasurements and Displays SupportedAdjacent Channel Leakage Ratio (ACLR), Spectrum Emission Mask (SEM), Channel Power, Occupied Bandwidth, Power vs. Time showing Transmitter OFF power for TDD signals and LTE constellation diagram for PSS, SSS with Cell ID, Group ID, Sector ID and Frequency Error.
General characteristics
GPIB SCPI-compatible, see programmer manual for exceptions

Ordering information

SignalVu® Vector Signal Analysis software is compatible with all DPO/MSO5000 Series digital oscilloscopes with firmware version 6.1.1 and DPO7000, DPO/DSA/MSO70000 Series digital oscilloscopes with firmware version V5.1.0 or higher. SignalVu Essentials (Opt. SVE) provides basic vector signal analysis and is required for all other analysis options.
Options
Opt. SVE SignalVu Essentials - Vector Signal Analysis SoftwareOpt. SV23 WLAN 802.11a/b/g/j/p measurement application (requires Opt. SVE, requires oscilloscope of bandwidth of 2.5 GHz or above)Opt. SV24 WLAN 802.11n measurement application (requires Opt. SV23, requires oscilloscope of bandwidth of 2.5 GHz or above)Opt. SV25 WLAN 802.11ac measurement application (requires Opt. SV24, requires oscilloscope of bandwidth of 6.0 GHz or above)Opt. SV26 APCO P25 measurement applicationOpt. SV27Bluetooth Basic LE Tx Measurements (requires Opt. SVE, requires oscilloscope of bandwidth of 2.5 GHz or above)Opt. SV28LTE Downlink RF measurements (requires Opt. SVE, requires oscilloscope of bandwidth 1 GHz or above). Not available on DPO/MSO5000 SeriesOpt. SV30IEEE802.11ad SC Wideband Waveform Analysis (requires Opt. SVE, requires oscilloscope of bandwidth 4 GHz or above)Opt. SVP Advanced Signal Analysis, including pulse measurements (requires Opt. SVE)Opt. SVM General Purpose Digital Modulation Analysis (requires Opt. SVE)Opt. SVT Settling Time, Frequency, and Phase (requires Opt. SVE)Opt. SVO Flexible OFDM with support for 802.11a/j/g and 802.16-2044 (fixed WiMAX) modulation types. Not available on the MSO/DPO5000 Series (requires instruments with Windows 7 operating system)Opt. SVA AM/FM/PM Modulation and Audio Measurements (requires Opt. SVE, (requires instruments with Windows 7 operating system)
SignalVu ordering and upgrade guide for new and existing instruments

Option ordering nomenclature for all oscilloscopes. Option SVE is required for all other options listed. Option SVO is not available on MSO/DPO5000 models.

For information on analysis software that runs on your personal computer, please see the SignalVu-PC datasheet.

New and existing models
Model Ordering on new instrument Upgrade existing instrument
MSO/DPO5000 Series Opt. SVE (Essentials) DPO-UP Opt. SVEE
DPO7000 Series Opt. SVE (Essentials) DPO-UP Opt. SVEM
DPO/DSA/MSO70000 Series ≤8 GHz Opt. SVE (Essentials) DPO-UP Opt. SVEH
DPO/DSA/MSO70000 Series >8 GHz Opt. SVE (Essentials) DPO-UP Opt. SVEU
Option SVE required for all other options listed Opt. SVT (Settling time) DPO-UP Opt. SVT
Opt. SVP (Pulse measurements) DPO-UP Opt. SVP
Opt. SVM (GP modulation analysis) DPO-UP Opt. SVM
Opt. SVO (OFDM) DPO-UP Opt. SVO
Opt. SVA (AM/FM/PM Audio) DPO-UP Opt. SVA
Opt. SV26 (APCO P25) DPO-UP Opt. SV26
DPO7000 and DPO/DSA/MSO70000 Series ≥2.5 GHz Opt. SV23 (IEEE802.11a/b/g/j/p) DPO-UP Opt. SV23
Option SV23 required for SV24 Opt. SV24 (IEEE802.11n) DPO-UP Opt .SV24
Option SV24 required for SV25 Opt. SV25 (IEEE802.11ac) DPO-UP Opt. SV25
DPO7000 and DPO/DSA/MSO70000 Series ≥2.5 GHz Opt. SV27 (Bluetooth) DPO-UP Opt. SV27
DPO7000 and DPO/DSA/MSO70000 Series ≥1 GHz Opt. SV28 (LTE Downlink) DPO-UP Opt. SV28
DPO/DSA/MSO70000 Series ≥4 GHz Opt. SV30 (IEEE 802.11ad) DPO-UP Opt. SV30
Legacy models DPO7000 Series, DPO/DSA/MSO70000 Series

Earlier DPO7000 and DPO/DSA/MSO70000 Series oscilloscopes may be retrofitted with SignalVu. These instruments use a Microsoft Windows XP operating system, have oscilloscope firmware version 5.1 or above, and are compatible with SignalVu version 2.3.0072. See upgrade nomenclature table above for ordering information. Option SVO (OFDM), Option SVA (AM/FM/PM Audio), and Options SV23, SV23, SV25, SV26, SV27, SV28, SV30 (WLAN, Bluetooth, WiGig, LTE and P25) are not available on instruments with Microsoft Windows XP.

Standard accessories Reference Manual (PDF)Printable Help (PDF)Programmer Manual (PDF)
版权所有:沈阳优尼沃仪器设备有限公司 辽ICP备2023006579号
网站建设:东道网络